Technical Details

Technical Details: Fixed Steel Ladder Body, Safety Cage & Platform Construction

Complete construction cards for every part of our fixed steel ladder with safety cage — ladder body (side rails, rungs, supports), the 800 mm round safety cage, resting platform, plus the full installation sequence and field details, engineered to GB 4053.1 and the 15J401 standard.

fixed steel ladder body construction technical drawing
Quick Answer

DengTAI fixed steel ladders are built with 60×10mm flat steel side rails, 25mm round bar rungs at 300mm spacing, and an 800mm diameter safety cage. Compliant with GB 4053.1, OSHA 1910.28 and EN ISO 14122-4. We provide complete construction drawings for every component.

System 1 — Ladder Body

Fixed Steel Ladder Body Construction

Nine construction cards cover every component of the ladder body: side rails, rungs, cross beams, adjustable feet, wall supports, gussets, connection pieces, ladder arms and the roof top sections.

Construction Card 1.1 — Side Rail

D1 / D18 / D19 / D24
fixed steel ladder side rail construction
Function: the two longitudinal main frames of the ladder; carry the climbing load and support every rung.
Profile-60×10 flat steel, 60mm wide × 10mm thick (normal); -60×12 thicker for damp / corrosive conditions
Length1196 / 1423 / 1796 / 2396 / 2623 / 3223 mm by run height; middle runs 1200 / 1800 / 2400 mm
Qty2 per run, mirror-symmetric
Unit weight5.63 – 15.18 kg
FixingsWelded to rungs & cross beams; lands via adjustable feet; fixed to wall via supports

Construction Card 1.2 — Rung (Tread)

D1 / D2 / D24
fixed steel ladder rungs with safety cage
Function: the climbing surface; must be slip-resistant.
Profileφ20 round steel (normal); φ25 for damp / corrosive conditions
Length600 mm (net ladder width)
SpacingVertical spacing ≤300 mm, uniform; first rung ≤450 mm above base level
Qty4–16 per run by height (WT5: 6–12 steps)
Unit weight1.48 kg
FixingsWelded to side rails at both ends, uniformly spaced

Rung Spacing — Detailed Design Guide

Rung spacing is a critical safety dimension that varies by standard. Getting it wrong causes trips, slips and accidents — especially when workers are descending with tools.

Standard-by-standard comparison:

  • OSHA 1910.28 (USA): 254–356 mm (10–14 inches) uniform spacing, center-to-center. First rung must be 150–450 mm above the base.
  • EN ISO 14122-4 (EU): Maximum 300 mm uniform spacing. First rung ≤ 400 mm above the reference level.
  • GB 4053.1 (China): Maximum 300 mm spacing, first rung 400–450 mm above ground.
  • AS 1657 (Australia): Maximum 300 mm, minimum 250 mm.

Why 300 mm is the sweet spot:

Too wide and workers miss a step, especially when descending. Too narrow and it's awkward to climb. 300 mm matches average human leg stride length for a 90° vertical climb, working for 95% of adult workers.

Common mistakes to avoid:

  • ❌ Making the bottom section too tall (first rung > 500 mm) — workers struggle to step up
  • ❌ Uneven spacing between sections — breaks rhythm and causes trips
  • ❌ Forgetting to adjust for platforms — the first rung above a rest platform should match base height

DengTAI design practice:

We use 300 mm uniform spacing for all our ladders, regardless of destination standard, because it meets or exceeds all requirements. The first rung is always 450 mm above the base, which works for both OSHA and EN ISO.

Construction Card 1.3 — Cross Beam

D24
caged ladder cross beam fixing
Function: ties the two side rails together, keeps ladder width stable and prevents spreading.
ProfileL50×5 angle steel
Length900 mm
Qty2–4 per run
Unit weight3.39 kg
FixingsWelded horizontally between the two side rails

Construction Card 1.4 — Adjustable Foot & Foot Pad

D10 / D12 / D15
fixed steel ladder adjustable foot on roof platform
Function: lets the ladder adapt to the longitudinal & transverse roof slope on landing, keeping it level.
ProfileFoot L50×5; pad L50×5 angle + φ10 / φ6 round steel
LengthFoot 280 / 805 / 780 mm; pad angle 80 mm; pad φ10 = 730 mm; pad φ6 = 100 mm
QtyFeet 2; pads 2–5 each
Unit weight0.30 – 3.03 kg
FixingsFoot and pad loosely connected, re-positioned to suit slope in both directions

Construction Card 1.5 — Wall Support

D18 / D19 / D24
caged ladder wall support on parapet
Function: fixes the ladder to the building wall (facade / parapet).
ProfileL70×6 angle steel
Length624 mm; fits wall thickness 500(200) / 560(260) mm (bracketed = parapet)
Qty2–4 per run
Unit weight2.08 kg
FixingsSupport passes through wall; bolts for temporary fixing only, then weld; types for composite-panel wall & hollow-brick wall (D18)

Construction Card 1.6 — Gusset Plate

D24
fixed steel ladder gusset plate wall fixing
Function: connects the support to the wall / ladder, increasing fixing stiffness.
Profile-60×8 flat steel
Length200 mm
Qty2 per run
Unit weight0.75 kg
FixingsWelded to the support, fixed against the wall

Construction Card 1.7 — Connection Piece

D17 / D24
caged ladder segment connection piece
Function: the node connecting ladder segments (top / middle / bottom).
Profile-50×6 flat steel
Length140 mm
Qty6–16 per run
Unit weight0.33 kg
FixingsConnection piece + bolts allow the top section to be adjusted down -100 to -500 mm

Construction Card 1.8 — Ladder Arm & Embedded Part

D10 / D24
fixed steel ladder arm roof connection
Function: the ladder arm extends onto the roof (eave) to fix the ladder top; the embedded part anchors the support.
ProfileArm L63×5 angle; embedded part M-1b -150×8 + anchor bar φ10
LengthArm 2890 / 2965 mm; embedded 150 mm; anchor 250 mm
QtyArms 2 / embedded 2 / anchors 8
Unit weightArm 13.93–14.29 kg; embedded 1.41 kg; anchor 0.15 kg
FixingsArm welded to roof; embedded part cast into wall

Construction Card 1.9 — Top Section Roof Detail (Aa / Ab / Ac)

D10 – D16
fixed steel ladder top section roof installation
Function: three top-section details matched to roof type (heavy / light sandwich-panel / cantilever / parapet).
AaHeavy roof: bolt-connected adjustable top; cage top fully bolted; foot + pad; L50×5 L=80 welded
Aa lightSandwich panel: L70×6 l=800 + extra L70×6; bolts + waterproof rubber gasket; with purlin
Ab / Ab lightHeavy: φ12 hole, R300. Light: flashing + extra purlin; L70×6 l=600; 6×100=600
Ab cantileverMetal sandwich-panel wall; 550 / 1050 / 500 / 150 / 200
Ac / Ac lightHeavy: R3000, φ800–1000, R76/R20. Light: flashing; parapet height >600–1200
Waterproofing: on light sandwich-panel roofs, coordinate roof waterproofing with the panel supplier; seal penetrations through insulated wall boards with sealant (D9).
System 2 — Safety Cage

Safety Cage Construction

Four construction cards cover the round 800 mm safety cage: cage overall, hoops, vertical bars and cage detail sections.

Construction Card 2.1 — Safety Cage Overall

D1 / D2 / D17
round safety cage fixed steel ladder
Function: surrounds the climbing space for fall protection.
StructureRound, diameter 800 mm
Top height1050 mm above roof / platform, with handrail
Start height3000 mm above base level
RequirementMandatory for single-run ≥7 m; C2/C3 on cantilever at ≥2.1 m
FixingsCage top section fully bolted for easy service

Construction Card 2.2 — Cage Hoop (Ring)

D24
safety cage hoop ring construction
Function: the circumferential hoops that form the round cage section.
Profile-50×6 flat steel
Length3208 / 1976 mm
Qty1–8 per run
Unit weight7.55 / 4.65 kg
FixingsCircumferential; welded / bolted to cage vertical bars

Construction Card 2.3 — Cage Vertical Bar

D24
safety cage vertical bars construction
Function: the vertical bars that string the hoops into a cage frame.
Profile-40×5 flat steel
Length3500 mm (main) / 188 mm (node)
Qty4–18 per run (WT: 5)
Unit weight5.50 / 9.40 kg
FixingsEvenly spaced vertically; connect with hoops; fixed to side rails / wall

Construction Card 2.4 — Cage Detail (Section)

D17
safety cage detail section drawing
Function: precise nodes where the cage meets the ladder and platform.
PartsHoop 50×6, rung, connection 50×6; bolts M10 / M20
DimCage bottom above ground 300 / 450 / 800 / 600 mm; top above platform 1050 mm; R400, 80° arc
FixingsCage bars fixed to side rail or wall; top joins Aa / Ab / Ac

Safety Cage Diameter — Standard Comparison

Cage diameter is a critical safety dimension — too narrow and workers feel cramped, too wide and it adds unnecessary cost. Different standards have slightly different requirements.

Standard-by-standard cage diameter:

  • OSHA 1910.28 (USA): Minimum 20 inches (508 mm) inside diameter. Most manufacturers use 686-762 mm (27-30 inches) for comfort.
  • EN ISO 14122-4 (EU): Minimum 600 mm inside diameter. We use 800 mm as standard for comfort.
  • GB 4053.1 (China): 650-800 mm diameter. 800 mm is our standard.
  • AS 1657 (Australia): Minimum 850 mm diameter — the strictest standard.

Why we use 800 mm as standard:

800 mm works for all standards except Australia (which needs 850 mm). It's comfortable for workers wearing harnesses and carrying tools. For Australian projects, we can upgrade to 900 mm on request.

Common mistakes to avoid:

  • ❌ Making the cage too narrow (under 600 mm) — workers feel cramped and may hesitate to climb
  • ❌ Cage starts too low (below 2.5-3 m) — workers can enter the cage area at the bottom and get stuck
  • ❌ Cage ends too low (below top platform) — no handrail at the top exit

DengTAI standard practice:

We use 800 mm diameter cages as standard, starting 2.5-3 m above the base and extending 1.0-1.2 m above the top platform. Hoop spacing is 1.5 m maximum, per all major standards.

System 3 — Resting Platform

Resting Platform Construction

Eight construction cards cover the platform: platform type & size, platform plate, main beam, handrail, support / pad / strap, embedded parts, concrete base & manhole, and column frame.

Construction Card 3.1 — Platform Type & Overall Size

D1 / D5 / D8 / D20 / D22 / D23
walk through resting platform caged ladder
Function: rest / transfer between multi-run ladder segments.
Walk-throughWidth 1800 mm (P1 / P2)
Side-entryWidth 1200 mm (P3 / P4)
Depth1500 mm (eave) / 1200 mm (parapet)
Spacing6 m vertical, ladder runs staggered

Construction Card 3.2 — Platform Plate

D26
resting platform plate construction
Function: the standing / passage surface of the platform.
Profile-1860×4 steel plate or -1260×4
Dim1530 / 1230 mm (clear span)
Unit weight89.36 / 71.84 / 60.53 / 48.66 kg
Qty1 per platform
FixingsLaid on and connected to the main beam

Construction Card 3.3 — Main Beam

D20 / D26
resting platform main beam steel structure
Function: the platform's main load-bearing beam; supports the plate and live load.
ProfileC12.6 channel or L70×6 angle
LengthChannel 4800 / 5208 / 4200 / 3600 mm; angle 5700 / 5100 / 4200 / 3600 mm
Unit weight59.52 – 23.08 kg
Qty1 per platform
FixingsMounted on supports / wall; after welding the frame, connect to support plate; bolted AND welded

Construction Card 3.4 — Platform Handrail (Rail + Post)

D20 / D26
platform handrail rail post construction
Function: the safety guardrail around the platform.
ProfileRail L50×4 + -30×4; post L50×4
LengthRail 4816 / 4216 / 3616 mm or 4824 / 4224 / 3624 mm; post 1090 mm
QtyRails 1–3, posts 8
Unit weightRail 14.73–3.41 kg; post 3.33 kg
FixingsRail height ~1050; cross beam raised to rail height (one side can rise as handrail); posts spot-welded to the platform plate

Construction Card 3.5 — Platform Support / Pad / Strap

D26
platform support pad strap wall anchor
Function: fixes the platform to the wall and transfers load.
ProfileSupport -300×14 or -100×14; pad -70×14; strap L70×6
LengthSupport 1140 / 840 mm or 300 mm; pad 200 mm; strap 300 mm
QtySupports 1–2, pads 4, straps 2
Unit weightSupport 37.59–3.30 kg; pad 1.54 kg; strap 1.92 kg
FixingsSupport anchored to wall; pad / strap assist fixing

Construction Card 3.6 — Platform Embedded Parts (M-2b / M-3b)

D26
platform embedded part anchor
Function: embedded anchors in the wall for the platform support.
ProfileM-2b -350×8 + anchor φ10; M-3b -240×10 + anchor φ12
LengthEmbedded 150 / 360 mm; anchor 250 / 440 mm
QtyEmbedded 2 / anchors 8; or embedded 1 / anchors 6
Unit weightEmbedded 3.30 / 6.78 kg; anchor 0.15 / 0.39 kg
FixingsCast into wall; platform support anchors onto them

Construction Card 3.7 — Platform Concrete Base & Manhole

D20 / D23
platform concrete base manhole
Function: concrete base under the platform beam; manhole for the ladder to pass through.
MaterialConcrete C20
Manhole900/(1100), 1500(200), 1140(840), 530(230), 1260(960) (bracketed = with manhole)
FixingsLadder passes through platform manhole; no manhole where platform sits on crane-catwalk plate

Construction Card 3.8 — Column Frame (Rectangular Column)

D21
platform column frame rectangular column
Function: fixes the platform to a freestanding rectangular column where no wall is available.
PartsConnection C18a, φ20, L50×5, M-4b(-80×8), anchor φ12; -120×80×8 + double nuts
LengthL50×5 = 100 mm; M-4b = 120 mm; anchor φ12 = 300 mm; b / h per project design
QtyConnections 2 / φ20 ×4 / L50×5 ×4 / M-4b ×4 / anchors 8
FixingsColumn frame also suits rectangular columns; tightened with double nuts
System 4 — Installation

Ladder Installation Sequence

Roof-access steel ladders are delivered in top / middle / bottom sections for easy handling and field assembly (segmentation is for construction convenience and does not appear in the drawing numbers).

Installation sequence — 7 steps

  1. Embed & set out — embed M-1b embedded parts with anchor bars in the wall / roof; mark ladder position and eave / parapet level. Position per roof type a / b / c (eave / parapet ≤600 / 600–1200).
  2. Fix supports — fix the L70×6 support and -60×8 gusset to the wall with temporary bolts (bolts for temporary fixing only, then weld).
  3. Assemble bottom section — build side rails + rungs + cross beam; rung spacing ≤300 mm, first rung ≤450 mm above base (sections C1 / C2 / C3).
  4. Assemble middle section — continue with 1200 / 1800 / 2400 mm sections (B1 / B2 / B3); fix to supports, temporary bolt then weld.
  5. Assemble top section — fit the Aa / Ab / Ac top per roof type; bolt-connected, adjustable down -100 to -500 mm to suit roof height.
  6. Fit the safety cage — hoops (-50×6) and vertical bars (-40×5) form the 800 mm round cage; top cage fully bolted for easy service; bottom at 3000 mm, top 1050 mm above roof.
  7. Roof finish & waterproofing — on light sandwich-panel roofs fit flashing + additional purlin; seal penetrations; coordinate waterproofing with the panel supplier.

Multi-run ladder (WT3) extra steps

  1. Fit resting platforms — between runs (6 m spacing) install walk-through P1 / P2 or side-entry P3 / P4; after welding the beam frame, connect to the support plate — bolted AND welded.
  2. Platform handrail — fit platform plate, main beam, handrail rails + posts; posts spot-welded to the plate.
  3. Extend the cage — the cage continues continuously through every run; runs staggered horizontally.

On-site Assembly

Segmented delivery for easy transport through doorways and tight spaces. Sections are bolted into position on site, then welded for permanent structural integrity. Our team provides remote-guided installation via video call if needed.

Steel-Frame Fixing

Ladders can be fixed directly to steel columns and structural frames during new construction, or retrofitted to existing steel structures. Custom bracket designs match your column profile and load requirements.

System 5 — Field Details

Installation & Field Details (by category)

5.1 Height Adjustment

ladder height adjustment top section
  • Top section bolt-connected, adjustable down -100 / -200 / -300 / -400 / -500 mm to suit roof height (D10–D16).
  • Actual height should equal or be less than the marked height; use top-section take-down to match.
  • Cage top 1050 mm above roof / platform fixed; cage bottom starts 3000 mm above base level.

5.2 Fixing & Welding

ladder fixing welding detail
  • Ladder-to-support joint: bolts for temporary fixing only, then weld (D18 / D19) — bolts locate, welding provides strength.
  • Platform: after welding the beam frame, connect to support plate — bolted AND welded (D20).
  • Handrail posts to platform plate: spot-weld (D20).
  • Embedded parts (M-1b / M-2b / M-3b / M-4b) cast into wall for support / platform anchoring.

5.3 Roof Waterproofing

roof waterproofing ladder detail
  • Light sandwich-panel roof: ladder-to-roof joint should be waterproofed together with the roof panel supplier (D11 / D13 / D16).
  • Where the support passes through the insulated end wall board: seal fully around the penetration or treat on site (D9).
  • Light roof uses flashing + additional purlin at the ladder-foot node (D13 / D16).

5.4 Slope Adaptation

ladder slope adaptation adjustable foot
  • Adjustable foot + foot pad loosely connected, re-positioned to suit roof slope in both longitudinal & transverse directions (D10 / D12 / D15).
  • Foot pad isometric / section / welded-frame detail shown on D10.

5.5 Safety Cage Details

safety cage installation detail
  • Cage is round 800 mm, built of hoops (-50×6) + vertical bars (-40×5).
  • Cage top section fully bolted for easy service (D10).
  • Single-run ladder ≥7 m must have a cage; C2 / C3 on cantilever at ≥2.1 m need a cage, hoop count added to schedule (D19).
  • Single-run below 7 m: no full cage, only a safety cage at the top; B1–B3 schedule excludes cage vertical bars (D24).

5.6 Platform & Wall Relationship

platform wall relationship detail
  • Platform width: 1800 mm (walk-through, climber passes through) vs 1200 mm (side-entry, lower run at the side).
  • Platform depth: 1500 mm (eave) / 1200 mm (parapet), by ladder-to-wall distance.
  • Platform vertical spacing 6 m, runs staggered.
  • Manhole (ladder passes through): dashed = manhole position; no manhole where platform sits on crane-catwalk plate; bracketed dims = with manhole (900/(1100) etc.).

5.7 Column Frame Details

column frame double nut detail
  • Column frame also suits rectangular columns; column dims b, h per project design (D21).
  • Tightened with double nuts, M-4b(-80×8) + anchor φ12.
Appendix

Bolt Schedule & Key Dimension Quick Reference

Bolt connection schedule

BoltSizeUnit weightUse
M1030 mm long0.02 kgSegment connection / platform
M1680 mm long0.13 kgPlatform
M20——Safety cage connection

Key dimensions — quick reference

SystemKey values
LadderNet width 600; rung spacing ≤300; first rung ≤450; rail -60×10; rung φ20
Safety cageDiameter 800; top above 1050; bottom above 3000; hoop -50×6; bar -40×5
PlatformWidth 1800 / 1200; depth 1500 / 1200; spacing 6 m; plate -1860×4; beam C12.6

Technical FAQ

What is the standard cage diameter?

Our standard safety cage is 800mm in diameter, built with -50×mm hoop rings and -40×5 vertical bars. This meets OSHA, EN ISO and GB requirements for worker clearance and fall protection.

What is the standard rung spacing?

Rung spacing is 300mm maximum, with the first rung 450mm above the base. This is compliant with OSHA 1910.28, EN ISO 14122-4 and GB 4053.1 standards.

Do you provide installation drawings?

Yes. Every order includes complete construction drawings, assembly guides, and load test reports. We also provide remote technical support during installation.

Get a Quote for Your Fixed Steel Ladder

Send your drawing, height and cage / platform requirement — we reply within 24 hours.

Tel: +86 152 2651 7938  ·  Email: 289810621@qq.com

Request a Quote

References: OSHA 1910.28 · EN ISO 14122-4 · ISO 9001

Last updated: · DengTAI Stair Manufacturing Co., Ltd. · Shijiazhuang, Hebei, China